REAGENTS PROVIDED AND RECONSTTTUTION

REAGENTS(Store at 2-8℃)

1×96 WELLS

0.5×96 WELLS

RECONSTTTUTION

96/48-wells microtiter plates

1

0.5

Ready-to-use

Plastiv cover

2

1

Ready-to-use

Standard: 800ng/ml

1Vials  (0.6ml)

0.5Vials  (0.3ml)

See reagents preparation on page 3

Blank control

1Vials  (1.0ml)

1Vials   (0.5ml)

Ready-to-use

Standard Diluent

1Vials  (5ml)

1Vials   (2.5ml)

Ready-to-use

Biotinylated anti-Co IV

1Vials  (6ml)

1Vials   (3.0ml)

Ready-to-use

Streptavidin-HRP

1Vials  (10ml)

1Vials   (5.0ml)

Ready-to-use

Washing Buffer

1Vials  (20ml)

1Vials   (10ml)

50× concentrate

Substrate  A

1Vials  (6.0ml)

1Vials   (3.0ml)

Ready-to-use

Substrate  B

1Vials (6.0ml)

1Vials   (3.0ml)

Ready-to-use

Stopping Solution

1Vials  (6.0ml)

1Vials   (3.0ml)

Ready-to-use

Sample Diluent

1Vials  (12ml)

1Vials   (6.0ml)

Ready-to-use

MATERIAL REQUIRED BUT NOT PROVIDED

  • Distilled water
  • Pipettes:10ul、50ul、100ul、200ul、1000ul。
  • Vortex mixer and magnetic stirrer.

SAFETY

  • For research use only
  • Avoid any skin contact with H2SO4 and TMB. In case of contact, wash thoroughly water.
  • Do not eat, drink, smoke or apply cosmetics where kit reagents are used.
  • Do not pipette by mouth.

PROCEDURAL NOTES/LAB.QUALITY CONTROL

  • When not in use, kit components should be stored refrigerated or frozen as indicated on vials or bottles. All reagents should be warmed to room temperature before use. Lyophilized standards should be discarded after use.
  • Once the desired number of strips has been removed, immediay reseal the bag to protect the remaining strips from edterioration.
  • Cover or cap all reagents when not in use.
  • Do not mis or interchange reagents between different lots.
  • Do not use reagents beyond the expiration date of the kit .
  • Use a clean disposable plastic pipette tip for each reagent, standard, or specimen addition in order to avoid cross-contamination, for the dispensing of H2SO4 and substrate solution, avoid pipettes with metal parts.
  • Use a clean plastic container to prepare the washing solution.
  • Thoroughly mix the reagents and samples before use by agitation or swirling.
  • All residual washing liquid must be drained from the wells by efficient aspiration or by decantation followed by tapping the plate forcefully on absorbent paper. Never insert absorbent paper directly into the wells.
  • The TMB solution is light sensitive. Avoid prolonged exposure to light, also, avoid contact of the TMB solution with metal to prevent colour development. Warning TMB is toxic avoid direct contact with hands. Dispose off properly. If a dark blue colour develops within a few minutes after preparation, this indicates that the TMB solution has been contaminated and must be discarede. Read absorbances within 1 hour after completion of the assay.
  • When pipetting reagents, maintain a consistent order of addition from well-to-well. This will ensure equal incubation times for all wells.
  • Respect incubation times described in the assay procedure.

SPECIMEN COLLECTION\ PROCESSING AND STORAGE

  • Serum---Avoid any inintentional stimulation of the cells by the procedure. Use pyrogen\endotoxin free collecting tubes. Serum should be removed rapidly and carefully from the red cells after clothing. For that, after clothing, centrifuge at approximay 1000×g for 10 min and remove serum.
  • Plasma---EDTA\ citrate and heparin plasma can be assayed. Spin samples at 1000×g for 30 min remove particulates. Harvest plasma.
  • Cell culture supernatants---Remove particulates and aggregates by spinning at approximay 1000×g for 10 min.
  • Storage---If not analyzed shortly after collection, samples should be aliquoted(250-500ul) to avoid freeze-thaw cycles and stored frozen at -70℃. Avoid multiple freeze-thaw cycles of frozen specimens. When possible, avoid use of badly hemolyzed or lipemic sera. If large amounts of particles are present, this should be removed prior to assay by centrifugation or filtration.
  • Recommendation---Do not thaw by heating at 37℃ or 56℃. Thaw at room temperature and make sure that sample is compley thawed and homogenous before assaying.

PREPARATION OF REAGENTS

  • Standards: Standard have to be reconstituled with the volume of standard buffer diluent indicated on the vial. This reconstitution produces a stock solution of 800ng/ml Co IV. Allow standard to stand for 5
  • minutes with gentle swirling prior to making dilutions. Serial dilutions of standard must be made before each assys and cannot be stored.

800 ng/ml

(6  Standard)

Original density 50ul。

400 ng/ml

(5  Standard)

100ul  6 Standard  +100ul diludent

200 ng/ml

(4  Standard)

100ul  5 Standard  +100ul diludent

100 ng/ml

(3  Standard)

100ul  4 Standard  +100ul diludent

50 ng/ml

(2  Standard)

100ul  3 Standard  +100ul diludent

25 ng/ml

(1  Standard)

100ul  2 Standard  +100ul diludent

0 ng/ml

Blank Control

50ul。


  • Washing buffer 50×concentrate:  Dilute 50 times in distilled water.

ASSAY METHOD

  • Before use, mix all reagents thoroughly without making foam.
  • Determine the number of microwell strips required to test the desired number of samples,plus appropriate number of wells needed for running blanks standards. Each sample, standard and blank should be assayed in duplicate. Remove sufficient microwell strips from the pouch.
  • Add 50ul of standard diluent to standard wells B1,B2,  C1,C2,  D1,D2,  E1, E2,  F1,F2. Reconstitute standard vial with the appropriate volume as described in the chapter reagents preparation. Preparation. Pipet 100ul of standard into wells A1 and A2 (see plate scheme below). Transfer 50ul from A1 and A2 to B1 and B2 wells. Mix the contents by repeated aspirations and ejections. Take care not to scratch the inner surface of microwells. Repat this procedure from the wells B1,B2 to wells C1,C2 and from wells C1,C2 to D1,D2 and so on creating two parallel rows of Co IV standard dilutions ranging,Add 50ul of standard diluent to the bland wells.
  • Dilute samples 1:1 distribing 50ul of sample into 50ul of dilluent ,Add 50ul of diluted sample to wells..
  • Add 50ul of diluted biotinylated anti-Co IV to all wells.
  • Cover with a plate vover and incubate for 1 hour at 37℃.
  • Remove the cover and wash the plate as follows: ⑴ aspirate the liquid from each well, ⑵ dispensse 0.3ml of washing solution into each well. ⑶ Aspirate again the contet of each well after 0.5 minute. ⑷ Repeat steps ⑵ and ⑶ three times.
  • Distribute 80ul of streptavidin-HRP solution to all wells, including blank wells.
  • Cover and incubate 30 min at 37℃.
  • Remove the cover and empty wells, Wash microwell strips according to step, Proceed immediay to the next step.
  • Add 50ul Substrate A and Substrate B to each well。Incubate for 10 min at 37℃。
  • The enzyme-substrate reaction is stopped by quickly pipetting 50ul of H2SO4. stop reagent into each well, including the blank wells, to compley and uniformly inactivate the enzyme. Results must be red immediay after the addition of H2SO4.
  • Read absorbance of each well on a spectrophotometer using 450nm as the primary wavelength and optionally 620nm (610nm to 650nm is acceptable ) as the reference wavelength.

SUGGESTED PLATE SCHEME

 

Standard

concentrations(ng/ml)

 

A

800

800

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

B

400

400

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

C

200

200

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

D

100

100

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

E

50

50

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

F

25

25

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

G

0

0

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

H

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

sample

LIMITATIONS OF THE PROCEDURE

Do not extrapolate the standard curve beyond the max  standard curve point. The dose-response is non-linear in this region and good accruacy is difficult to obtain.

CALCULATION OF RESULTS

The minimum detectable concentration in this assay is estimated to be 1.0ng/ml 

了解更多ELISA試劑盒說明書,歡迎您致電給我公司業務員索取,上海恒遠為您提供中、英文兩種語言詳細說明書。2015年RD試劑盒新品即將上市,敬請關注:




主站蜘蛛池模板: 一级毛片在线播放| 在线视频精品一区| 中文字幕亚洲另类天堂| 亚洲第一成人在线| 欧美日韩亚洲综合在线观看| 亚洲人在线| 最新国产高清在线| 中文字幕 欧美日韩| 亚洲国产精品VA在线看黑人| 亚洲无码电影| 午夜性刺激在线观看免费| 思思热精品在线8| 日韩专区欧美| 国产精品视频久| 午夜福利亚洲精品| 成人综合在线观看| 欧美国产综合色视频| 亚洲大学生视频在线播放| 国产精品久久久精品三级| 国产男人天堂| 九色视频线上播放| 国产九九精品视频| 亚洲无码在线午夜电影| 国产微拍一区二区三区四区| 在线观看精品自拍视频| 日韩人妻精品一区| 国产麻豆精品在线观看| 中文字幕 91| 日韩视频精品在线| 日韩 欧美 小说 综合网 另类| 日韩一区二区在线电影| 国产综合在线观看视频| 国产成年无码AⅤ片在线| 亚洲天堂日韩在线| 国产后式a一视频| 亚洲天堂精品视频| 国产乱人视频免费观看| 黄色网址免费在线| 婷婷久久综合九色综合88| 国产又色又刺激高潮免费看| 亚洲成肉网| 在线国产资源| 91精品情国产情侣高潮对白蜜| 国产人妖视频一区在线观看| 国产精品亚洲专区一区| 一区二区影院| 色妺妺在线视频喷水| 亚洲看片网| 国产性猛交XXXX免费看| 青青草一区二区免费精品| 日本黄色a视频| 亚洲国产看片基地久久1024| 成·人免费午夜无码视频在线观看 | 亚洲高清国产拍精品26u| 国产第四页| 亚洲国产成人精品青青草原| 99热6这里只有精品| 青草精品视频| 国产视频大全| 天堂av综合网| 亚洲成人黄色在线| 五月天福利视频 | 91精品啪在线观看国产| 亚洲色精品国产一区二区三区| 日韩av无码精品专区| 97一区二区在线播放| 欧美成人手机在线观看网址| 一级一级一片免费| 国产美女在线免费观看| 免费看黄片一区二区三区| 99国产精品免费观看视频| 熟女日韩精品2区| 国产门事件在线| 国产女主播一区| 亚洲人成网站18禁动漫无码| 亚洲国产欧美国产综合久久| 又爽又大又黄a级毛片在线视频| 99这里只有精品6| 亚洲香蕉久久| 99视频在线免费观看| 国产迷奸在线看| 国产成人一区在线播放|